TECPEL CO LTD
home products Electronic Instrument Differential Probe

Differential Probe

CE approval:Reliable Quality
Company Info
Company Published: 2005
Online Postings: Products , Selling Leads
Country/Territory: Taiwan
Business Type: Manufacturer
Number of Employees: 11 - 50 People
Contact this Member

« Prev Product 1 2 3 4 5 6 7 ... Next Product »
You can use the keys "←", "→" on your keyboard to turn pages
Terms of Payment: T/T
Supply Ability: 100 Piece/Pieces per Week
Delivery Lead Time: 15
Detailed Product Description

Differential Probe 25MHz ( DP-25)

Product ID: DP-25
25MHz Differential Probe
3 RANGE ATTENUATOR.
2 POWER SOURCE.
1000V INPUT CAT III
LOW BATT. AUTO OFF.
SEPARATING DESIGN.CONVENIENT, DURABLE.
MEET CE, IEC 1010, EN 61010, UL 3111.
Band width (-3dB, 50?[ load): DC-25MHz . ( x 20: DC~15MHz)
Accuracy : +/- 2% at 20-30'C 70% RH after 20 minutes warm up.
Attenuation : x 20, x 50, x 200 ( Into 1M Ohm scope ) ; x 40, x 10
, x 400 ( Into 50 Ohm load )
Maximum operation Voltage ( DC + peak AC ) :
<= 140V at x 20
<= 350V at x 50
<= 1300V at x 200
Maximum input Differential Voltage : 1300V ( DC + peak AC ) or 1000V RMS
Maximum input Voltage to Ground : 1000V ( DC + peak AC ) or 600V RMS
Common Mode Rejection Ratio ( CMRR ):
60Hz : >10,000 : 1
100Hz: >1,000 : 1
1MHz: > 300 : 1
Noise :<= 2 mV rms ( Into 50 Ohm load )
Input Impedance :
2M Ohm, 2.3 PF between inputs and ground.
4M Ohm, 1.2 PF between inputs.
Power :One internal 9V alkaline battery or external 6V-9V DC.

FEATURES

  • The DP-25 FET input differential probe provieds a safe means of measuring circuits with floating potentials up to 1000 V ( DC+ peak AC ) from ground and 1300V ( DC + peak AC ) differential.
  • The DP-25 converts the high voltage differencial input signal to a low voltage ground refereced signal for display on any Oscilloscope.
  • The output BNC of DP-25 is calibrted to drive a high impedance ( 1M Ohm) load.
  • INSTRUCTION FOR USE
  • Connect the output BNC of DP-25 to the input BNC of the Oscilloscope by the accessory BNC cable.
  • Adjust the vertical offset of the Oscilloscope if necessary.
  • Set the select proper range of the DP-25 and the V / DIV of the Oscilloscope according to the scale conversion chart.
  • Scale conversion chart : The effective V / DIV is the attenuation factor of x 20, x 50, x 200 multiplied by the scale factor of the Oscilloscope. It will be twice when the 50 ?[ load was used. For example, with the range set at x 200,
  • and the scope set to 0.5 V / DIV, the effective V / DIV equals 200 x 0.5 or 100 V, with the 50 Ohm load was used, it becomes 200V, the power consumption will increase too.
  • NOTE:If the voltage of the input signal exceeeds the linear range of the setting range.The signal output of
  • the DP-25 would not accurately, the wave form display will be cut off.

Differential Probe Differential Probe

Send a message directly to this member
« Prev Product 1 2 3 4 5 6 7 ... Next Product »
You can use the keys "←", "→" on your keyboard to turn pages

Other Products from this Supplier

Contact Us

TECPEL CO LTD
[Taiwan]

Street Address : 4F-1, No.225, Sec.3, Heping East Rd., Taipei 11056,

City : Taipei

Province/State : TW

Country/Region : Taiwan

View Contact Details

Email this page Bookmark this page Print this Page

Contact this Member

Minimize